Date: 2 March 2012 15:54
Dear All,
----------
From: Regina Kettering
----------
From: Ethan Merritt
TLS uses very few parameters, and is especially useful at low resolution.
At 3.3A I would recommend trying a TLS model _instead_ of refining
individual B factors.
NCS restraints also help a lot at low resolution.
So the drop is believable, but...
You should first worry about "lots of waters were placed".
It's there that many extra parameters have been added, perhaps leading
to over-fitting. I would not expect 3.3A data to justify placement of
more than a handful of waters at most.
If you're parameter counting, you might note that 5 water molecules add
more parameters than 1 TLS model. But the TLS model may improve the model
everywhere, whereas the waters will only suppress a few local difference
density peaks.
cheers,
Ethan
----------
From: Thomas Womack
Rajesh;
I am not sure that you have a high enough data:refinement parameters ratio to refine TLS. It just adds more parameters to refine that can lead to over-refinement of your model, especially at the 3.3 A.
----------
From: Francis E Reyes
I've found the following article to be useful in defining suitable refinement strategies at a particular resolution.
1. Mueller, M., Jenni, S. & Ban, N. Strategies for crystallization and structure determination of very large macromolecular assemblies. Curr Opin Struct Biol 17, 572–579 (2007).
It can be used as a rough guide line at the start of your refinement (incomplete model, fresh off of molecular replacement) with slow increase of refinement parameters the better your model becomes (and as Rfree permits).
F
Francis E. Reyes M.Sc.
----------
From: Rajesh kumar
I have few more details....
----------
From: Pavel Afonine
Hi,
At 3.3A I would recommend trying a TLS model _instead_ of refining
individual B factors.
----------
From: Ian Tickle
See http://ww1.iucr.org/comm/cnom/adp/finrepone/finrepone.html
Section 1.5 Comments about terminology
Cheers
-- Ian
----------
From: Jacob Keller
----------
From: Pavel Afonine
Thanks Ian,
----------
From: Ian Tickle
> Parameters" over anything ele, because, given that Atomic Displacement
> Parameters can be parameterized in many different ways, it makes it easier
> to operate with such terms like:
>
> - isotropic Atomic Displacement Parameters (isotropic ADP);
> - anisotropic Atomic Displacement Parameters (anisotropic ADP);
> - group Atomic Displacement Parameters (group ADP);
> - group isotropic Atomic Displacement Parameters (group isotropic ADP;
> example: when refining one isotropic ADP per set of selected atoms);
> - group anisotropic Atomic Displacement Parameters (group anisotropic ADP;
> example TLS);
> - ... etc, etc...
>
> (no intention to open another "can of worms" ! -:) )
"atomic" throughout? In fact isn't "group (an)isotropic Atomic
Displacement Parameter" a contradiction in terms? Surely it can be
either a group parameter or an atomic parameter but not both at the
same time?
I think the worms are already out and making good their escape :).
Cheers
-- Ian
----------
From: Jacob Keller
Can't there be a "group of atoms?"
*******************************************
Jacob Pearson Keller
----------
From: Ian Tickle
> Can't there be a "group of atoms?"
or to a group of atoms?
Cheers
-- Ian
----------
From: Joseph Cockburn
Hi Rajesh,
If you're seeing a lot of extra density coming up in the map in regions
where you previously added waters, is it possible that this extra density
corresponds to a part of your protein that you previously thought was
disordered and is thus missing from the current model? At this resolution
you wouldn't expect to see many waters.
Also, to the best of my knowledge, the relative weighting of the X-ray and
geometry terms in BUSTER is set by the program so as to produce a rmsd in
bond lengths equal to a target value. The default value of this is 0.01
Ang (I think) but you can change this using the -r option on the command
line. Using a lower value will reduce the weight on the X-ray term and may
lower the R/R-free gap.
Best wishes,
Joe
From: Eleanor Dodson
Presumably your data is quite anisotropic, and low resolution, so it is quite likely that a TLS model will give much better description of the B factors than more classical refinement.
Modelling solvent at that resolotion will be tricky of course.
Elesnor
Professor Eleanor Dodson
From: Rajesh kumar
----------
From: Eleanor Dodson
No comments on much of your message but I cannot believe you can get better results by cutting anisotropic 2.1A data to 3.3A!!
You MUST be throwing away valuable experimental information,, remember crystallography is not about getting low R factors but about getting a model consistent with your experiment.
eleanor