Date: 7 February 2012 08:31
----------
From: Eleanor Dodson
Well - it shouldnt!
Check if there is some problem..
Eleanor
----------
From: Robbie Joosten
Hi Dialing,
Most water picking tools are rather overenthusiastic and end up placing some waters at places where they should not be. This causes some overfitting and an increase of R-free. I'm hideously old-fashioned and recommend conservatively building waters by hand.
There are some good validation tools that help get rid of excess water: centrifuge in PDB_REDO does the basic work; "check/delete waters" in Coot highlights other suspicious waters; WHAT_CHECK checks hydrogen bonding thoroughly, finds nonsense clusters of water and also finds possible ions. It must be noted that all these tools break down at very high resolution where you may get alternate waters. Fortunately, this problem doesn't occur very often.
Cheers,
Robbie
From: Pavel Afonine
Dialing,
No comments: